{ "id": "cat_c32_acert", "manufacturer": "Caterpillar", "model_name": "C32 ACERT", "category": "engine_main", "typical_systems": ["main_engine"], "specs": { "power_kw": 1081, "rpm_nominal": 2300, "weight_kg": 2440, "length_m": 2.04, "width_m": 1.30, "height_m": 1.30, "fuel_consumption_lph": 245 }, "description": "Caterpillar C32 ACERT, V12, 32.1 L. Aplicación yates rápidos 70-100 pies / patrulleros / pilot boats. Twin turbo intercooled.", "data_source": "seed_estimate", "default_sensors": [ { "id": "rpm", "name": "RPM", "unit_si": "rpm", "range_normal_min": 0, "range_normal_max": 2400, "alarm_high_value": 2350, "alarm_high_priority": "high", "default_signal_type": "pulse_magnetic_pickup" }, { "id": "oil_press", "name": "Presión aceite", "unit_si": "bar", "range_normal_min": 3.0, "range_normal_max": 5.5, "alarm_low_value": 1.5, "alarm_low_priority": "emergency", "default_signal_type": "4-20ma" }, { "id": "oil_temp", "name": "Temperatura aceite", "unit_si": "C", "range_normal_min": 60, "range_normal_max": 110, "alarm_high_value": 120, "alarm_high_priority": "high", "default_signal_type": "rtd_pt100" }, { "id": "coolant_temp", "name": "Temperatura refrigerante", "unit_si": "C", "range_normal_min": 65, "range_normal_max": 95, "alarm_high_value": 100, "alarm_high_priority": "emergency", "default_signal_type": "rtd_pt100" }, { "id": "boost_press", "name": "Presión sobrealimentación", "unit_si": "bar", "range_normal_min": 0.0, "range_normal_max": 2.5, "default_signal_type": "4-20ma" }, { "id": "alternator_v", "name": "Voltaje alternador", "unit_si": "V", "range_normal_min": 27.0, "range_normal_max": 29.0, "alarm_low_value": 24.0, "alarm_low_priority": "high", "default_signal_type": "voltage_divider" }, { "id": "load_pct", "name": "Carga del motor", "unit_si": "%", "range_normal_min": 0, "range_normal_max": 100, "default_signal_type": "4-20ma" }, { "id": "running_hours", "name": "Horas totales", "unit_si": "h", "range_normal_min": 0, "range_normal_max": 80000, "default_signal_type": "4-20ma" }, { "id": "start_cmd", "name": "Comando arranque", "unit_si": "bool", "default_signal_type": "relay_no" }, { "id": "stop_cmd", "name": "Comando parada", "unit_si": "bool", "default_signal_type": "relay_no" }, { "id": "running_state", "name": "Estado motor en marcha", "unit_si": "bool", "default_signal_type": "dry_contact" }, { "id": "estop_active", "name": "E-stop activado", "unit_si": "bool", "default_signal_type": "dry_contact" } ] }