sprint-2: rule engine + auto-assigner + equipment editor + biblioteca
Wizard pasos 5-7 ahora funcionales (1-4 ya estaban en Sprint 1).
vmssailor/studio/designer/rule_engine.py
- RuleContext, RuleEngine, EquipmentProposal
- Lee library/rules/*.yaml y aplica reglas heuristicas
- Filtra por vessel_type, vessel_subtype, length_overall_m range
- Selecciona candidato segun condiciones 'when' (loa min/max)
- Genera tag_prefix con sustitucion {side}/{idx}
vmssailor/studio/designer/port_auto_assigner.py
- auto_assign() greedy: 1 bus Modbus RTU + tarjetas dedicadas para motores/gensets
- Tarjeta auxiliar compartida para resto de equipos
- Mapea SignalType -> ChannelType (AI/DI/DO/RPM)
- Genera TagBindings con scaling apropiado por tipo de senal
- Respeta capacidades 10/5/4/1 de AR-NMEA-IO-v1.0
- AssignmentReport con cards + tags + warnings
vmssailor/studio/wizard/step_05_equipment.py
- Tabla con propuestas del rule engine
- Checkboxes accept/reject + edicion inline de columnas
- Boton 'Regenerar' para re-aplicar reglas
vmssailor/studio/wizard/step_06_refinement.py
- Vista resumen de equipos aceptados
vmssailor/studio/wizard/step_07_topology.py
- Llama auto_assign sobre los equipos materializados
- Muestra tabla de tarjetas con uso por canal (DO/DI/AI/RPM)
- Lista warnings de capacidad
vmssailor/studio/editors/equipment_editor.py
- CRUD de Equipment del proyecto activo
- Tabla editable inline (tag_prefix, name, model_ref, system_id, coords, deck)
- Dialog modal para agregar equipos
- Senal projectMutated para refrescar canvas + sidebar
vmssailor/studio/main_window.py
- Layout actualizado: splitter vertical en panel derecho
(canvas arriba + equipment editor abajo)
- _on_project_mutated() re-distribuye al sidebar y canvas
Biblioteca expandida (Sprint 2 brief: 5-7 yates, 10+ motores, gensets, bombas):
- vessels: + azimut_grande_32m, princess_y85, trawler_32m_offshore, patrol_coastal_30m (total: 6)
- engines: + cat_c32_acert, mtu_16v_2000_m96, yanmar_8lv_370 (total: 5)
- gensets: + kohler_28efkozd, onan_qd13500 (total: 3)
- pumps: + jabsco_36800, grundfos_cm10 (NUEVO categoria pumps)
Tests (tests/studio/test_designer.py, 10 nuevos, total 120/120):
- Rule engine: load default, propose engines, candidate picking por LOA
- auto_assign builds topology compatible with Project (Pydantic validation)
- Equipment editor smoke
VesselWizard.build_project() ahora materializa equipment + topology + tags
desde las propuestas y la asignacion automatica del paso 7.
Criterios Sprint 2:
- uv run vms-studio crea proyecto completo desde wizard con equipos + tags + topologia
- vms-validate-library: OK 6 vessels, 10 equipment, 1 rules
- 120/120 pytest verde, ruff clean
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,32 @@
|
||||
{
|
||||
"id": "kohler_28efkozd",
|
||||
"manufacturer": "Kohler",
|
||||
"model_name": "28EFKOZD",
|
||||
"category": "genset",
|
||||
"typical_systems": ["genset"],
|
||||
"specs": {
|
||||
"power_kw": 22.4,
|
||||
"rpm_nominal": 1500,
|
||||
"weight_kg": 450,
|
||||
"length_m": 1.30,
|
||||
"width_m": 0.70,
|
||||
"height_m": 0.85,
|
||||
"voltage_v": 230,
|
||||
"current_a": 97,
|
||||
"fuel_consumption_lph": 7.0
|
||||
},
|
||||
"description": "Kohler 28EFKOZD genset marino diésel, 28 kVA / 22.4 kW @ 1500 rpm 50 Hz. Aplicación yates motor 50-70 pies. Cabina silenciosa estándar.",
|
||||
"data_source": "seed_estimate",
|
||||
"default_sensors": [
|
||||
{ "id": "rpm", "name": "RPM", "unit_si": "rpm", "range_normal_min": 0, "range_normal_max": 1550, "default_signal_type": "pulse_magnetic_pickup" },
|
||||
{ "id": "oil_press", "name": "Presión aceite", "unit_si": "bar", "range_normal_min": 2.0, "range_normal_max": 4.5, "alarm_low_value": 1.0, "alarm_low_priority": "emergency", "default_signal_type": "4-20ma" },
|
||||
{ "id": "coolant_temp", "name": "Temperatura refrigerante", "unit_si": "C", "range_normal_min": 70, "range_normal_max": 95, "alarm_high_value": 102, "alarm_high_priority": "emergency", "default_signal_type": "rtd_pt100" },
|
||||
{ "id": "voltage_l1", "name": "Tensión L1", "unit_si": "V", "range_normal_min": 220, "range_normal_max": 240, "default_signal_type": "voltage_divider" },
|
||||
{ "id": "current_l1", "name": "Corriente L1", "unit_si": "A", "range_normal_min": 0, "range_normal_max": 100, "alarm_high_value": 110, "alarm_high_priority": "high", "default_signal_type": "4-20ma" },
|
||||
{ "id": "freq", "name": "Frecuencia", "unit_si": "Hz", "range_normal_min": 49.5, "range_normal_max": 50.5, "default_signal_type": "pulse_inductive" },
|
||||
{ "id": "running_hours", "name": "Horas", "unit_si": "h", "default_signal_type": "4-20ma" },
|
||||
{ "id": "start_cmd", "name": "Arranque", "unit_si": "bool", "default_signal_type": "relay_no" },
|
||||
{ "id": "stop_cmd", "name": "Parada", "unit_si": "bool", "default_signal_type": "relay_no" },
|
||||
{ "id": "breaker_status", "name": "Breaker principal", "unit_si": "bool", "default_signal_type": "dry_contact" }
|
||||
]
|
||||
}
|
||||
Reference in New Issue
Block a user